A Simple Methods for Determination of Methylene Blue using Smartphone-Based as Digital Image Colorimetry

Authors

  • Muhamad Diki Permana Department of Chemistry, Faculty Mathematics and Natural Sciences, Universitas Padjadjaran Sumedang, Jawa Barat 45363, Indonesia https://orcid.org/0000-0002-5871-5004
  • Lintang Kumoro Sakti Department of Chemistry, Faculty Mathematics and Natural Sciences, Universitas Padjadjaran Sumedang, Jawa Barat 45363, Indonesia
  • Annisa Luthfiah Department of Chemistry, Faculty Mathematics and Natural Sciences, Universitas Padjadjaran Sumedang, Jawa Barat 45363, Indonesia https://orcid.org/0000-0002-5512-5375
  • M Lutfi Firdaus Graduate School of Science Education, Bengkulu University, Bengkulu 38371, Indonesia https://orcid.org/0000-0002-5627-5834
  • Takahiro Takei Center for Crystal Science and Technology, University of Yamanashi, Kofu, Yamanashi 4008511, Japan
  • Diana Rakhmawaty Eddy Department of Chemistry, Faculty Mathematics and Natural Sciences, Universitas Padjadjaran Sumedang, Jawa Barat 45363, Indonesia
  • Iman Rahayu Department of Chemistry, Faculty Mathematics and Natural Sciences, Universitas Padjadjaran Sumedang, Jawa Barat 45363, Indonesia

DOI:

https://doi.org/10.48048/tis.2023.5149

Keywords:

Methylene blue, Digital image, Smartphone, Colorimetry, Standard addition

Abstract

The advancement of smartphones that produce high-resolution photos has made their use even more developed. One application that is currently developing is a digital image produced as colorimetry. Digital image-based colorimetry is an easy and simple determination method and can be an alternative for analyzing dyes quantitatively. In this method, the color response of the digital image is analyzed, namely red-green-blue (RGB) with values from 0 to 255. This data is extracted from digital images using ImageJ 1.52a software for quantitative determination. In this study, 2 standard methods were used, namely external standards and standard addition to evaluating the most suitable method to obtain accurate measurements. In addition, 2 methods were used to determine the relationship of response to methylene blue levels. The 1st method used simple linear regression of each color red, green, or blue (univariate). The 2nd method is used in multivariate linear regression of the 3 colors red, green, and blue. The accuracy of the method was validated using UV-Vis spectrophotometry as the reference method. The results showed that the multivariate models produced very good accuracy, namely precision of up to 99 % compared to the simple regression method with the univariate.

HIGHLIGHTS

  • Smartphone cameras can be applied easily as a simple, fast, and inexpensive colorimetric method for quantitative analysis of methylene blue content
  • The univariate models for external standard and standard addition methods showed up to 90 % precision for fish drug samples against UV-Vis spectrophotometric methods
  • The multivariate models for the external standard method provide up to 99 % precision results for fish drug samples against UV-Vis spectrophotometric methods·         

GRAPHICAL ABSTRACT

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

References

AR DiSanto and JG Wagner. Pharmacokinetics of highly ionized drugs I: Methylene blue whole blood, urine and tissue assays. J. Pharm. Sci. 1972; 61, 598.

M Oz, DE Lorke, M Hasan and GA Petronaiou. Cellular and molecular actions of methylene blue in the nervous system. Med. Res. Rev. 2010; 31, 93.

IAW Tan, AL Ahmad and BH Hameed. Adsorption of basic dye on high-surface area activated carbon prepared from coconut husk: Equilibrium, kinetic and thermodynamic studies. J. Hazard. Mater. 2008; 154, 337-46.

YC Wong, YS Szeto, WH Cheung and G McKay. Adsorption of acid dyes on chitosan - equilibrium isotherm analyses. Process Biochem. 2004; 39, 695.

NF Gaudette and JW Lodge. Determination of methylene blue and leucomethylene blue in male and female Fischer 344 rat urine and B6C3F1 mouse urine. J. Anal. Toxicol. 2005; 29, 28.

SJ Kim, DJ Ha and TS Koo. Simultaneous quantification of methylene blue and its major metabolite, azure B, in plasma by LC‐MS/MS and its application for a pharmacokinetic study. Biomed. Chromatogr. 2014; 28, 518.

J Qi, X Li, H Zheng, P Li and H Wang. Simultaneous removal of methylene blue and copper (II) ions by photoelectron catalytic oxidation using stannic oxide modified iron (III) oxide composite electrodes. J. Hazard. Mater. 2015; 293, 105.

V Springer, F Avila and M Avena. A simple strategy for methylene blue determination in human and veterinary dosage forms by digital imaging. J. Anal. Chem. 2020; 75, 958.

ML Firdaus, W Alwi, F Trinoveldi, I Rahayu, L Rahmidar and K Warsito. Determination of chromium and iron using digital image-based colorimetry. Procedia Environ. Sci. 2014; 20, 298.

A Fatoni, A Numnuam, P Kanatharana, W Limbut, C Thammakhet, PA Thavarungkul. Highly stable oxygen-independent glucose biosensor based on a chitosan-albumin cryogel incorporated with carbon nanotubes and ferrocene. Sens. Actuators B Chem. 2013; 185, 725.

M Serhan, M Sprowls, D Jackemeyer, M Long, ID Perez, W Maret, N Tao and E Forzani. Total iron measurement in human serum with a smartphone. In: Proceedings of the AIChE Annual Meeting Conference, Orlando. 2019.

Y Fan, J Li, Y Guo, L Xie and G Zhang. Digital image colorimetry on smartphone for chemical analysis: A review. Measurement 2021; 171, 108829.

ML Firdaus, A Aprian, N Meileza, M Hitsmi, R Elvia, L Rahmidar and R Khaydarov. Smartphone coupled with a paper-based colorimetric device for sensitive and portable mercury ion sensing. Chemosensors 2019; 7, 25.

Ö Kap, V Kılıç, JG Hardy and N Horzum. Smartphone-based colorimetric detection systems for glucose monitoring in the diagnosis and management of diabetes. Analyst 2021; 146, 2784.

J Wongthanyakram and P Masawat. Rapid low-cost determination of lead (II) in cassava by an iPod-based digital imaging colorimeter. Anal. Lett. 2019; 52, 550.

A Kumar, A Bera and S Kumar. A smartphone‐assisted sensitive, selective and reversible recognition of copper ions in an aqueous medium. ChemistrySelect 2020; 5, 1020-8.

M Pohanka, J Zakova and I Sedlacek. Digital camera-based lipase biosensor for the determination of paraoxon. Sens. Actuators B Chem. 2018; 273, 610.

J Guo, JX Wong, C Cui, X Li and HZ Yu. A smartphone-readable barcode assay for the detection and quantitation of pesticide residues. Analyst 2015; 140, 5518.

P Masawat, A Harfield and A Namwong. An iPhone-based digital image colorimeter for detecting tetracycline in milk. Food Chem. 2015; 184, 23.

OK Ostroukhova and LG Zenkevich. A comparison of the external standard and standard addition methods for the quantitative chromatographic determination of pesticide concentrations in plant samples. J. Anal. Chem. 2006; 61, 442.

LN Viana and TD Saint’Pierre. Direct determination of Cr and Ni in oil samples by isotope dilution and external standard calibration using inductively coupled plasma mass spectrometry. Microchem. J. 2019; 151, 104219.

ED Salin, M Antler and G Bort. Evaluation of the simultaneous use of standard additions and internal standards calibration techniques for inductively coupled plasma mass spectrometry. J. Anal. At. Spectrom. 2004; 19, 1498.

IV Nikolaeva, SV Palesskiy and AA Kravchenko. Evaluation of the matrix effect and selection of reference samples for the ICP-MS trace elements determination in geological samples. Mosc. Univ. Chem. Bull. 2022; 77, 94.

D Harvey. External standards or standard additions? selecting and validating a method of standardization. J. Chem. Educ. 2002, 79, 613.

T Hashiguchi, M Hashiguchi, H Tanaka, K Fukushima, T Gondo and R Akashi. Quantitative analysis of seven plant hormones in Lotus japonicus using standard addition method. Plos One 2021; 16, e0247276.

ML Firdaus, E Saputra, SM Ginting, S Wyantuti, DR Eddy, L Rahmidar and B Yuliarto. Smartphone-based digital image colorimetry for non-enzymatic detection of glucose using gold nanoparticles. Sens. Bio Sens. Res. 2022; 35, 100472.

G Landon, C Bouvier-Capely, A Legrand, T Sontag, G Finance, M Saint-Hilaire, F Rebière, X Millot, V Renaud-Salis and M Agarande. Validation and comparison of two calibration methods for the measurement of stable iodine in the urinary matrix by ICP-MS: Standard addition vs. external calibration. Am. J. Anal. Chem. 2017; 8, 245.

P Abbyad, J Tromp, J Lam and E Salin. Optimization of the technique of standard additions for inductively coupled plasma mass spectrometry. J. Anal. At. Spectrom. 2001; 16, 464.

C Wheelan. Naked statistics: Stripping the dread from the data. WW Norton & Company, New York, 2013.

S Seidi, M Rezazadeh, Y Yamini, N Zamani and S Esmaili. Low voltage electrically stimulated lab-on-a-chip device followed by red-green-blue analysis: a simple and efficient design for complicated matrices. Analyst 2014; 139, 5531.

Downloads

Published

2023-01-23

How to Cite

Permana, M. D. ., Sakti, L. K., Luthfiah, A., Firdaus, M. L., Takei, T. ., Eddy, D. R., & Rahayu, I. (2023). A Simple Methods for Determination of Methylene Blue using Smartphone-Based as Digital Image Colorimetry. Trends in Sciences, 20(4), 5149. https://doi.org/10.48048/tis.2023.5149