Study of Noise Annoyance and Vibration of Constructal Designed Window Air Conditioner

Authors

  • Selva Pandian Ebenezer College of Engineering, National University of Science & Technology, Muscat 130, Sultanate of Oman
  • Achintya Kumar Pramanck Department of Mechanical Engineering, National Institute of Technology, Durgapur, West Bengal 713209, India
  • KP Ramachandran College of Engineering, National University of Science & Technology, Muscat 130, Sultanate of Oman
  • Pradeep Kumar Krishnan College of Engineering, National University of Science & Technology, Muscat 130, Sultanate of Oman

DOI:

https://doi.org/10.48048/tis.2022.2693

Keywords:

Noise, Window air conditioner, Constructal, Vibration

Abstract

Industrial, residential and commercial noise levels are to be maintained for acoustic comfort living conditions. Sound annoyance is a sensation of discontentment linked with any driving force from machines or a circumstance. It is certain that, noise can harm human hearing capacity and brain neuron cells. Novelty of this study was the design of window air conditioner with modified heat exchanger coils with phase change material and water were used as refrigerants. Noise and vibration assessment of the constructal designed window air conditioner (CDWAC) and normal window air conditioner (NWAC) with the conventional vapor compression system was carried out. The noise levels, daily exposure noise level, noise criteria levels of the developed window air conditioner was found to be satisfactory according to the British Standard 4142 and noise at work regulations 1789.

The noise criteria for the CDWAC with phase change material and water exhibited a better performance around 50 dB whereas the NWAC with vapor compression system was around 60 dB.

For normal window AC the RMS value is about 0.62 and constructal window AC is about 0.38. peak amplitude was observed as 0.346 m/s2 in the CDWAC whereas it was about 0.512 m/s2 for NWAC compressor. The amplitude of vibration is very nominal in between 2 to 2.5 s in CDWAC and the peak variation is same as in 1.5 s. Results reveal that the noise and vibration performance of the construction designed window air conditioner was better than the NWAC.

HIGHLIGHTS

  • The design of constructal window air conditioner was an attempt to minimize one of the disorders or imperfections in the system that is the noise level created by the air conditioner during its operation
  • Noise and vibration analysis of constructal designed window air conditioner was studied in comparison with the normal window air conditioner
  • Vibration analysis was carried out through the experimental investigation
  • Time domain analysis and spectral analysis of both the air conditioners were performed and the curves were plotted for better understanding of the performances of both the air conditioners in connection with vibration during operation
  • In sum, it is found that constructal law based design of window air conditioner performs better than the normal window air conditioner


GRAPHICAL ABSTRACT

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

References

PHT Zannin and F Ferraz. Assessment of indoor and outdoor noise pollution at a university hospital based on acoustic measurements and noise mapping. Open J. Acoust. 2016; 6, 71-85.

SPHuang and RP Lai.Frequency characteristics of interior noises in houses. In: Proceedings of the 2005 World Sustainable Building Conference, Tokyo, Japan. 2005, p. 1503-8.

HM Shivraj and N Kapilan. Analysis of domestic split unit air conditioning system of outdoor unit. Int. J. Eng. Res. Gen. Sci. 2016; 4, 128-34.

V Wagner, H Enigk, T Beitz and KW Kallus. Subjective and objective evaluation of the air conditioning sound. J. Ergonomics 2014; 4,131.

T Tannert and U Hesse.Noise effects in capillary tubes caused by refrigerant flow. In: Proceedings of theInternational Refrigeration and Air conditioning Conference, West Lafayette, Indiana. 2016, p. 1562.

Fact Sheet and Acoustic Terminology.Noise technical fact sheet 7: Sound insulation for air conditioners and other noise from residential machines, The City of Adelaide, 2004.

GZ Gedik, NY Akdag, F Kiraz, B Sener and R Cacan.Evaluation of mass housing settlements in terms of wind and noise control: Istanbul and Diyarbakir as a case. J. Environ. Eng. Landsc. Manag. 2017; 25, 389-401.

E Sellappan and K Janakiraman.Environmental noise from construction site power systems and its mitigation. Noise Vib. Worldw. 2014; 45, 14-20.

SK Tang.Noise indices for assessing domestic air conditioner noise. Noise Vib. Worldw. 2006; 37, 10-4.

B Hay and MF Kemp. Frequency analysis of air conditioning noise in landscaped offices. J. Sound Vib.1972; 23, 375-81.

S Jachimowicz and K Gladyszewska-Fiedoruk. The noise produced by the air handling units depending on the type of engine. In: Proceedings of the 10th International Conference on Environmental Engineering, Vilnius, Lithuania. 2017, p. 20.

A Bejan and S Lorente. The constructal law of design and evolution in nature. Philos. Trans. R. Soc. B: Biol. Sci. 2010; 365, 1335-47.

A Bejan and MR Errera.Complexity, organization, evolution, and constructal law. J. Appl. Phys. 2016; 119, 074901.

AF Miguel.Natural flow systems: Acquiring their constructal morphology. Int. J. Des. Nat. Ecodyn. 2010; 5, 230-41.

M Lorgulescu andR Beloiue. Vibration and current monitoring for Fault’sdiagnosis of induction motors. Ann. Univ. Craiova Electr. Eng. Ser. 2008; 57, 102-7.

Z Wen, Y Zhang, Y Hu, R Zhang, H Gu and J Zhang. Research on low frequency vibration of rotary compressor. In: Proceedings of the 23rdInternational Compressor Engineering Conference, West Lafayette, Indiana. 2016, p. 1424.

MK Amirinejhad, MRanjbarand MKarimkhany.Effects of impeller gap on rotor vibration in a highspeed centrifugal compressor: A numerical and experimental analysis. Int. J. Eng. 2017; 30, 814-20.

OKavianipour and AM Khoshnood.Vibration suppression of fuel sloshing using sub band adaptive filtering. Int. J. Eng. 2015; 28, 1507-14.

SP Ebenezer, AK Pramanick and KP Ramachandran. Window air conditioner with orthodox refrigerants. Int. J. Eng. 2020; 32, 322-7.

G Zaza, AD Hammou, A Benchatti and H Saiah. Fault detection method on a compressor rotor using the phase variation of the vibration signal. Int. J. Eng. 2017; 30, 1176-81.

C Bujoreanu and M Benchea. Experimental study on HVAC sound parameters. In: Proceedings of the 7th International Conference on Advanced Concepts in Mechanical Engineering, Iasi, Romania. 2016, p. 012051.

C Wu and X Lei. Noise control and sound quality evaluation of outdoor unit of split air-conditioner. J. Meas. Eng. 2016; 4, 58-69.

HS Han, WB Jeong, S Aoyama and JY Mo. Experimental analysis for reducing refrigerant-induced noise of 4-way cassette type air conditioner. J. Mech. Sci. Tech. 2009; 23, 1456.

Downloads

Published

2022-02-15

How to Cite

Ebenezer, S. P. ., Pramanck, A. K. ., Ramachandran, K. ., & Krishnan, P. K. . (2022). Study of Noise Annoyance and Vibration of Constructal Designed Window Air Conditioner. Trends in Sciences, 19(5), 2693. https://doi.org/10.48048/tis.2022.2693